Applicable cells |
All shapes or sizes of polymer and cylindrical lithium-ion cells. |
Channel control and management |
Circuit interface:switch type, independent control Data update time: 100ms, efficiency:60% |
Main units |
Charge and discharge control box, battery tray |
Charge and discharge test mode |
Constant current, constant power, constant voltage, constant current-constant voltage, pulse, hibernation |
Test and control of current and voltage |
Charge and discharge voltage range:0V-5V Voltage accuracy:±0.1%FS,Resolution:1mV Charge and discharge current range:0A-500A Current accuracy:±0.1%FS |
Overall unit |
The overall unit adopts standard frame type modular structure design. Every 8 independently controlled channels adopt one 3U standard case. Each charge and discharge control case can be installed or debugged independently which can facilitate system maintenance and maintain a good EMC. The heating unit is designed with independent air duct using AC fan for compellent exhausting. |